http://www.pelco.com/

Pelco IXE20C

CathexisVision Camera Integration
Driver:


  Datasheet
Unicast  
Number Of Streams : 2
Format : H264
Audio : Not Supported
Resolution : Stream Dependant
Multicast  
 Format : H264
Resolution : Stream Dependant
Motion Detection  
Trigger String :

Motion messages are constructed of the zone name (if present) and the uppercase characters of the anaytic function:

:

eg. If we enable AdaptiveMotion and set the Zone name to “Zone 1” the message trigger will be:

“Zone 1:AM”

If the analytic function does not specify a zone name when set up on the camera, ommit . The message trigger for SabotageDetection will be:

“SB”

If the message trigger is set to “STARTMOTION”, all message triggers from the camera will trigger the event.

Settings  
PTZ Control : Implemented, but has not been tested.
Cathexis Software : 5042d1 and later
Camera Firmware : 1.6.13.9080-A1.4657
Limitations :

    • Video streams need to be setup on camera web interface.
    • Only H.264 is supported.
    • Refer to  http://trac.cat.co.za/support/wiki/pelcosetup for setup notes
    • Please refer to the following page for firmware version 1.9 change notes: Pelco Firmware V1.9

     

Pelco Camera Integration Guide